ENGINEERING GENERAL
SHEET METAL, HEAT EXCHANGERS, SHEETMETAL CAD
y factor
FOR A KNOWN DEVELOPED LENGTH THE PROE CALCULATES
DL = Y*T
WERE Y = Y FACTOR
T = SHEET THICKNESS
DL = DEVELOPED LENGTH